Top Curve
Symbol
Analogue Detectors 1251BPI
1251BPI Ionization detectors incorporate a unique single source, dual chamber design to respond quickly and dependably to a broad range of fires. Address selection from 0 to 159 allows the use of 0 to 99 on F100A and 0 to 159 on F120A (fitted with compatible firmware).

Analogue Detectors 1251 (Previous Model)
1251 Ionization detectors incorporate a unique single source, dual chamber design to respond quickly and dependably to a broad range of fires.

Analogue Detectors 2251BPI
2251BPI Photoelectric detectors unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Address selection from 0 to 159 allows the use of 0 to 99 on F100A and 0 to 159 on F120A (fitted with compatible firmware).

Analogue Detectors 2251 (Previous Model)
2251 Photoelectric detectors unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources.

2251CTL 2251CTLE-34-IV  Photo, Thermal, CO & IR Multi-criteria
2251CTLE is a detector that uses software algorithms to combine Carbon Monoxide, Photoelectric, Thermal and Infra-red sensing elements with addressable-analogue communications giving reliable fire detection whilst allowing the detector to reject many common causes of nuisance alarm. Valid addresses on F100A and F120A are 1 to 99.

22051TLE-34-IV 22051TLE-34-IV  Photo, Thermal, & IR Multi-criteria
22051TLE-34-IV is a detector that uses software algorithms to combine Photoelectric, Thermal and Infra-red sensing elements with addressable-analogue communications giving reliable fire detection whilst allowing the detector to reject many common causes of nuisance alarm. Valid addresses on F100A and F120A are 1 to 99.

Analogue Detectors 2251TMBPI
2251TMBPI Acclimate is a Photoelectric smoke detector with a supplementary 57° C Thermal. It uses advanced on board software to combined the signals from the photo and thermal elements. Address selection from 0 to 159 allows the use of 0 to 99 on F100A and 0 to 159 on F120A (fitted with compatible firmware).

5251BPI 5251BPI
5251BPI intelligent Thermal Detector with a fixed temperature of 57° C . It uses a state-of-the-art single thermistor sensing circuit to provide early warning of developing fires. Address selection from 0 to 159 allows the use of 0 to 99 on F100A and 0 to 159 on F120A (fitted with compatible firmware).

5251BPI 5251RBPI
5251RBPI intelligent Rate of Rise Thermal Detector. It uses a state-of-the-art single thermistor sensing circuit to provide early warning of developing fires. Address selection from 0 to 159 allows the use of 0 to 99 on F100A and 0 to 159 on F120A (fitted with compatible firmware).

New
5251B-WP
5251B-WP
5251BPI intelligent Weatherproof Thermal Detector with a fixed temperature of 57° C . It uses a state-of-the-art single thermistor sensing circuit to provide early warning of developing fires. Address selection from 0 to 159 allows the use of 0 to 99 on F100A and 0 to 159 on F120A (fitted with compatible firmware). Requires handheld programmer CP500 to set the detector address.

New
5251RB-WP
5251RB-WP
5251RBPI intelligent Weatherproof Rate of Rise Thermal Detector. It uses a state-of-the-art single thermistor sensing circuit to provide early warning of developing fires. Address selection from 0 to 159 allows the use of 0 to 99 on F100A and 0 to 159 on F120A (fitted with compatible firmware). Requires handheld programmer CP500 to set the detector address.

7251 7251
7251 Pinnacle is an intelligent, Laser-based Photoelectric smoke detector featuring extensive on board signal processing capabilities designed to improve smoke response.

Remote LED Indicator Unit DETREM
Pertronic Industries' Remote LED Indicator Unit is a remote annunciator designed and manufactured by Pertronic Industries for use on System Sensor Conventional (Series 100 and 300) and Analogue (Series 200) Detectors as well as Pertronic Remote LED Indicating Heat Detectors.

Base B524IEFT-1
B524IEFT-1 Isolator Base that is designed for use with all System Sensor 200 and 500 series analogue addressable detectors. It prevents an entire communications loop from being disabled when a short circuit occurs.

Base B501
The B501 is a plug in Detector Base intended for use in an intelligent system with screw terminals provided for power (+) and (–), and remote annunciator connections. The communication takes place over the power (+) and (–) lines.

WB-1 WB-1AP-IV
The WB-1 Detector Adapter Base Enclosure is recommended in humid environments and can accommodate B401, B401R and B501 bases.

SMK400 SMK400
The SMK400 allows conventional & analogue bases to be surface mounted.

BCK-200B BCK-200B
Black detector cover kit for 200 Series detectors and 100 Series 2151BPI detector.

Base B524HTR
The B501 The B524HTR heater base incorporates a number of heater resistors, driven from a separate supply designed to provide an element of heating to the detector to reduce condensation in very cold applications.

Bottom Curve