2151BPI Detector

Conventional photoelectric smoke detector. Available in white and ivory

Thermistor Heat Detector

Conventional thermistor indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-approved

Thermistor Heat Detector w Remote

Conv. thermistor indicating heat detectors Terminals for remote indicator Alarm threshold: 57 °C (blue), 77 °C (yellow) NZS 4512-approved

Thermistor Heat Det. Weatherproof

Conventional thermistor indicating heat detectors. Weatherproof. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-approved

Thermistor Heat Det. Alk. Resistant

Conv. thermistor indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow) NZS 4512-approved

THD for Freezers

Conventional thermistor indicating heat detector. Fixed alarm threshold: 57 °C NZS 4512 type (blue) Suitable for freezers and cool stores

IHD Kit

Conventional bi-metallic indicating heat detectors with remote sensor. Fixed threshold: 57 °C (blue) or 125 °C (black). NZS 4512-compliant

2351E Detector

Conventional photoelectric smoke detector

2351TEM Detector

Conventional multi-criteria detector. Photoelectric smoke, configurable as low, medium, or high sensitivity. 58 °C rate of rise heat sensor

4351E Detector

Conventional heat detector with 78 °C fixed alarm temperature threshold

5351E Detector

Conventional rate of rise heat detector with 58 °C fixed alarm temperature threshold

5351TE Detector

Conventional heat detector with 58 °C fixed alarm temperature threshold

IHD*-V

Conventional indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant

IHD*E-V

Conventional indicating heat detectors. Encapsulated. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant

DETREM Remote LED Indicator

Remote LED indicator

IHD*R-V

Conv. indicating heat detectors. Terminals for remote indicator. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant

IHD*EAR-V

Conv. indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant

HD*-V

Conv. non-indicating heat detectors, with or without encapsulation. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512:1997-compl

2W-B Detector

2-wire conventional photoelectric smoke detector

2WTA-B Detector

Multi-criteria detector, 2-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and alarm sounder

4W-B Detector

4-wire conventional photoelectric smoke detector

4WT-B Detector

Multi-criteria detector, 4-wire, with photoelectric smoke sensor and heat sensor with 58 °C fixed alarm threshold

4WTR-B Detector

Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and relay

4WTAR-B Detector

Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold, sounder, and relay

2012/24AUSI Detector

Photoelectric Smoke Alarm 4-wire, 12 V / 24 V with 9 V battery AS 3786:2014

PC614 Detector

Conventional carbon monoxide (CO) and rate-of-temperature-rise heat detector. Suitable for detecting slow-smoldering and fast-flaming fires.

Sensitivity Reader

This tool is to measure the sensitivity of System Sensor model 2151BPI conventional photo-electronic smoke detectors.