CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Projects

Pertronic F100A Fire System for Hagley Oval Pavilion

 

The Hagley Oval in Christchurch’s South Hagley Park has been used for provincial and local cricket since 1867. After the recent earthquakes Hagley Oval was upgraded into a world-class cricket venue to replace the earthquake-damaged AMI Stadium. Its first international cricket match – the opening game in the ICC Cricket World Cup between NZ and Sri Lanka – was held in February 2015.

A major part of the upgrade was the new pavilion, designed by Athfield Architects and opened in September 2014. Protecting the tent-like pavilion presented some interesting challenges, especially as the architects did not want services encroaching on fabric ceiling surfaces, such as in the main function room.

The fire detection system is supervised by a Pertronic F100A analogue addressable panel, installed by Fire Fighting Pacific, Canterbury. The function room is protected by an aspirating smoke detection system with sampling pipes between the outer and inner layers of the double-skin roof, and capillary tubes through holes in the inner skin. Linear heat detection cable is threaded into pockets spanning the entire roof.

201602 3

Areas with conventional ceilings have point-type smoke and heat detectors. A remote mimic display in th e Player’s Lobby provides duplicate control and display. 

 

Posted in Pavilion; Tagged NZ - Canterbury;

CONTACT US

Categories

  • Accommodation
  • Aged Care
  • Apartment Building
  • Art Gallery
  • Arts Centre
  • Café
  • Court House
  • Educational
  • Energy
  • Entertainment
  • Event Centre
  • Government Building
  • Health Care
  • Hospital
  • Hotel
  • Office Building
  • Pavilion
  • Prison
  • Retail
  • Retirement Village
  • Sawmills
  • Scott Base
  • Shopping Mall
  • Sports Venue
  • Transport Centre
  • Tunnel
  • Underground Car Park

Tags

  • Antarctica
  • Australia - NSW
  • Australia - QLD
  • Australia - VIC
  • China
  • Fiji
  • NZ - Auckland
  • NZ - Canterbury
  • NZ - Manawatu-Wanganui
  • NZ - Northland
  • NZ - Wellington
VIEW ALL PROJECT PROFILES

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL