CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Amplifiers

Evacuation Amplifier 60 Watt, 24 Volt with Integral Tones

Products » Alarm (Alerting) Devices » Amplifiers
Pertronic

EA60 Amplifier

Datasheet
Manual
ENQUIRE ABOUT THIS PRODUCT

The Pertronic EA60 amplifier is a high performance amplifier for the Pertronic F220, F100A and F16e fire alarm systems.

With excellent sound clarity, this amplifier is suitable for all non-emergency and emergency applications including occupant warning, public address, and background music.

The on-board keyboard and LCD display provide speaker load measurement and other menu-driven test and management features, together with user-friendly configuration of operating settings, announcements, and signals. Configuration files can be saved and loaded via USB, allowing a single configuration file to be copied to multiple amplifiers.

The built-in audible signal generator produces signals and announcements for many purposes including the evacuation and alert signals specified in AS 4428.16. Additional signals including custom voice messages are easily added via USB.

The Pertronic EA60 features three audio inputs suitable for local and/or remote microphones and external audio sources including background music.

With a large number of easily configurable options, the Pertronic EA60 satisfies a wide range of audio system requirements.

Audible Signals

  • Library of pre-defined audible signals including:
    • AS 4428.16 evacuation and alert signals
    • 50 pre-defined tones
    • 23 pre-defined voice messages
    • Pre- and post-announcement chimes
  • Fully configurable signal priority system
  • Four voice message profiles: Australian male & female; and British male & female
  • User-friendly system for creating custom signals
  • Custom voice messages, voice profiles, and tones may be added to the on-board library via USB stick
  • Fire evacuation signal may be disabled or over-ridden with “Priority 1” signal

Features

  • 60 watt rms class D amplifier with supervised 100 volt rms line output
  • Excellent sound clarity for maximum intelligibility
  • Menu-controlled power measurement allows output load to be checked during installation or maintenance
  • User-friendly configuration with on-board keyboard and 5 x 16 character backlit display
  • Multiple EA60 and/or EA120 amplifiers may be factory-fitted to a single Pertronic fire panel
  • Three individually controlled balanced audio inputs
    • Input 1, PTT controlled, configurable as “Fire Mic” (supervised), “PA Mic” (supervised), or “Aux” input
    • Input 2, PTT controlled, configurable as “PA Mic” (supervised) or “Aux” input
    • Input 3, Vox controlled “Aux” input, configurable for mono or stereo sources, with built-in audio mixer to combine left and right stereo channels
  • Master-Repeater mode allows one master amplifier to drive up to seven repeater amplifiers
  • Configuration may be cloned via USB stick
  • ADM-4 interface provides up to 4 channels per line output, individually selectable by the fire panel
  • Supervised 24 volt dc 2-wire strobe (VAD) output:
    • Supports single or dual strobe systems
    • Configurable to activate on any fire panel event
    • Dual VAD colour determined by output polarity
  • Assignable form C relay, configurable to activate on any combination of Common Fault, Amplifier Active, Amplifier Disabled or Isolated, Test Alarm, PTT, FIP Active, Strobe On, or Bell-In Active
  • Isolated RS-485 interface to Pertronic analogue addressable fire panels
  • Twenty-event time-stamped history log
  • Compatible with Pertronic and third-party fire panels
  • Resettable country presets for AU or NZ standards
  • EA60 and EA120 amplifiers, and EAMIC, have been independently tested to AS 4428.16:2020, Grade 3, by an IANZ-Accredited laboratory
  • FPANZ Listing PI/409

Ordering Information

Product Code

Description

EA60

Evac Amplifier 60W, 24V DC with Integral Tones Voice Messages & VAD O/P


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL