Analogue Addressable Detectors
7351 Pinnacle
Pinnacleâ„¢ high-sensitivity analogue addressable smoke detector
2251TMBPI
"Acclimate" multi-criteria detector with photoelectric smoke sensor and 63 °C fixed (static) temperature thermistor heat sensor
2251BPI
Photoelectric analogue addressable plug-in smoke detector
5251BPI
Analogue addressable heat detector with 57 °C fixed (static) temperature threshold
5251RBPI
Analogue addressable rate of temperature rise heat detector with 57 °C fixed (static) temperature threshold
5251B-WP Detector
Weatherproof analogue addressable heat detector with 57 °C fixed (static) temperature threshold, including special base
5251RB-WP Detector
Weatherproof AA rate of temperature rise heat detector with 57 °C fixed (static) temperature threshold, including special base
Analogue Addressable Beam Detectors
BEAMLRK
Long Range Reflector (70 - 100 m).
Used with 6500SE-34 & 6500RSE
RTS151KIT
Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors
Analogue Addressable Duct Detectors
DNRW
Analogue addressable watertight non-relay photoelectric duct smoke detector
RTS151KIT
Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors
Conventional Detectors
2151BPI
Conventional photoelectric smoke detector. Available in white and ivory
Thermistor Heat Detector
Conventional thermistor indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-approved
Thermistor Heat Detector w Remote
Conv. thermistor indicating heat detectors Terminals for remote indicator Alarm threshold: 57 °C (blue), 77 °C (yellow) NZS 4512-approved
Thermistor Heat Det. Weatherproof
Conventional thermistor indicating heat detectors. Weatherproof. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-approved
Thermistor Heat Det. Alk. Resistant
Conv. thermistor indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow) NZS 4512-approved
IHD Kit
Conventional bi-metallic indicating heat detectors with remote sensor. Fixed threshold: 57 °C (blue) or 125 °C (black). NZS 4512-compliant
2351TEM
Conventional multi-criteria detector with a photoelectric smoke sensor and a rate of rise heat sensor with 58 °C fixed temperature threshold
4351E
Conventional heat detector with 78 °C fixed alarm temperature threshold
5351E
Conventional rate of temperature rise heat detector with 58 °C fixed alarm temperature threshold
5351TE
Conventional heat detector with 58 °C fixed alarm temperature threshold
IHD*-V
Conventional indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant
IHD*E-V
Conventional indicating heat detectors. Encapsulated. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant
IHD*R-V
Conv. indicating heat detectors. Terminals for remote indicator. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant
IHD*EAR-V
Conv. indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant
IHD*EK-V
Conventional encapsulated indicating heat detector & cable for harsh environments. Fixed threshold: 57 °C (blue), 125 °C (black)
HD*-V
Conv. indicating heat detectors, with or without encapsulation. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512:1997-compliant
2WTA-B
Multi-criteria detector, 2-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and alarm sounder
4WT-B
Multi-criteria detector, 4-wire, with photoelectric smoke sensor and heat sensor with 58 °C fixed alarm threshold
4WTR-B
Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and relay
4WTAR-B
Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold, sounder, and relay
2012/24AUSI
Photoelectric Smoke Alarm 4-wire, 12 V / 24 V with 9 V battery AS 3786:2014
PC614
Conventional carbon monoxide (CO) and rate-of-temperature-rise heat detector. Suitable for detecting slow-smoldering and fast-flaming fires.
Conventional Beam Detectors
BEAMLRK
Long Range Reflector (70 - 100 m).
Used with 6500SE-34 & 6500RSE
RTS151KIT
Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors
OSID Laser Tool
This tool clips into the eyeball on OSI/OSID beam smoke detectors. It produces a red laser beam showing the detector beam's target
Conventional Duct Detectors
D2-AUS
Conventional duct housing with 2151 detector, no relay, no tube
D4120
4-Wire Photoelectric + Relay Duct Smoke Detector (stand-alone only)
D4120W
Waterproof 4-Wire Photoelectric Duct Smoke Detector. Fitted with auxiliary relay with two form C (change-over) contacts.
RTS151KIT
Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors
Flame Detectors
Linear Heat Detection
LHD
Linear heat detection cable. Please note that Pertronic-Anbesec LHD Cable is preferred for new installations