Analogue Addressable Detectors
2251TMBPI
"Acclimate" multi-criteria detector with photoelectric smoke sensor and 63 °C fixed (static) temperature thermistor heat sensor
7351 Pinnacle
Pinnacleâ„¢ high-sensitivity analogue addressable smoke detector
5251BPI
Analogue addressable heat detector with 57 °C fixed (static) temperature threshold
5251RBPI
Analogue addressable rate of temperature rise heat detector with 57 °C fixed (static) temperature threshold
5251RB-WP
Weatherproof AA rate of temperature rise heat detector with 57 °C fixed (static) temperature threshold, including special base
5251B-WP
Weatherproof analogue addressable heat detector with 57 °C fixed (static) temperature threshold, including special base
Analogue Addressable Beam Detectors
RTS151KIT
Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors
Analogue Addressable Duct Detectors
DNRW
Analogue addressable watertight non-relay photoelectric duct smoke detector
RTS151KIT
Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors
Conventional Detectors
2351TEM
Conventional multi-criteria detector with a photoelectric smoke sensor and a rate of rise heat sensor with 58 °C fixed (static) threshold
4351E
Conventional heat detector with 78 °C static (fixed) temperature threshold
5351E
Conventional rate of temperature rise heat detector with 58 °C static (fixed) temperature threshold
5351TE
Conventional heat detector with 58 °C static (fixed) temperature threshold
IHD*-V
NZS 4512:2010-compliant indicating heat detectors with static (fixed) temperature threshold at 57 °C (blue dot) or 77 °C (yellow dot)
IHD*E-V
NZS 4512:2010-compliant indicating heat detectors with protective encapsulation. 57 °C (blue dot) or 77 °C (yellow dot)
IHD*R-V
NZS 4512:2010-compliant indicating heat detector with terminals for remote indicator. 57 °C (blue dot) or 77 °C (yellow dot)
IHD*EK-V
Encapsulated indicating heat detector & cable for harsh environments. Static (fixed) temperature threshold: 57 °C (blue) or 125 °C (black)
HD*-V
NZS 4512:1997 indicating heat detectors, with or without encapsulation. Static (fixed) temperature threshold: 57 °C (blue) or 77 °C (yellow)
2WT-B
Multi-criteria detector, 2-wire, with photoelectric smoke sensor and heat sensor with 58 °C fixed (static) temperature threshold
2WTA-B
Multi-criteria detector, 2-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed (static) threshold, and alarm sounder
4WT-B
Multi-criteria detector, 4-wire, with photoelectric smoke sensor and heat sensor with 58 °C fixed (static) threshold
4WTR-B
Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed (static) threshold, and relay
4WTAR-B
Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed (static) threshold, sounder, and relay
2012J
AS 3786-compliant domestic photoelectric smoke detector with sounder and form C relay
2012/24AUSI
Photoelectric Smoke Alarm 4-wire, 12 V / 24 V with 9 V battery AS 3786:2014
PC614
Conventional carbon monoxide (CO) and rate-of-temperature-rise heat detector. Suitable for detecting slow-smoldering and fast-flaming fires.
Conventional Beam Detectors
RTS151KIT
Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors
Conventional Duct Detectors
D2-AUS
Conventional duct housing with 2151 detector, no relay, no tube
D4120
4-Wire Photoelectric + Relay Duct Smoke Detector (stand-alone only)
D4120W
Watertight 4-Wire Photoelectric + Relay Duct Smoke Detector
RTS151KIT
Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors
Flame Detectors
Linear Heat Cable
Detector Accessories
In-Ceiling Detector Mount Kit
Kit of parts for mounting a point detector in a ceiling space.