Detectors

2151BPI Detector

Conventional photoelectric smoke detector. Available in white and ivory

OSID

Pulsed dual-wavelength smoke detector for open areas

DNR-AUS Duct Detector

Analogue Addressable Duct

D2-AUS Duct Housing

Conventional duct housing with 2151 detector, no relay, no tube

Pertronic-Anbesec LHD Cable

Heat sensing cable with a pair of twisted wires. The internal separator melts at a specific temperature, allowing contact between the wires

2251CPI Detector

C Series Intelligent addressable photoelectric smoke detector with programmable alarm threshold.

B501BI Isolator Base

Analogue Addressable Detector Base with Isolator

Thermistor Heat Detector

Conventional thermistor indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-approved

2251TMBPI Detector

"Acclimate" multi-criteria detector with photoelectric smoke sensor and 63 °C fixed (static) temperature thermistor heat sensor

DNRW Duct Housing

Analogue addressable watertight non-relay photoelectric duct smoke detector

D4120 Duct Detector

4-Wire Photoelectric + Relay Duct Smoke Detector (stand-alone only)

2251CTLE Detector

Photo, Thermal, CO & IR detector

Thermistor Heat Detector w Remote

Conv. thermistor indicating heat detectors Terminals for remote indicator Alarm threshold: 57 °C (blue), 77 °C (yellow) NZS 4512-approved

BEAMMMK Mounting Kit

Multi-mount kit for 6500SE-34 & 6500RSE

D4120W Weatherproof Duct Detector

Waterproof 4-Wire Photoelectric Duct Smoke Detector. Fitted with auxiliary relay with two form C (change-over) contacts.

Thermistor Heat Det. Weatherproof

Conventional thermistor indicating heat detectors. Weatherproof. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-approved

BEAMLRK Reflector

Long Range Reflector (70 - 100 m). Used with 6500SE-34 & 6500RSE

5251CPI Detector

C Series Intelligent addressable heat detector with programmable "fixed" temperature threshold.

RTS151KIT Remote Test Station

Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors

Sampling Tubes

Sampling Tubes for Duct Detectors

Thermistor Heat Det. Alk. Resistant

Conv. thermistor indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow) NZS 4512-approved

5251RCPI Detector

C Series analogue addressable "rate of rise" heat detector with programmable temperature threshold.

5251B-WP Detector

Weatherproof analogue addressable heat detector with 57 °C fixed (static) temperature threshold, including special base

THD for Freezers

Conventional thermistor indicating heat detector. Fixed alarm threshold: 57 °C NZS 4512 type (blue) Suitable for freezers and cool stores

BEAMSMK Mounting Kit

Surface-mount kit for 6500SE-34 & 6500RSE

5251RB-WP Detector

Weatherproof AA rate of temperature rise heat detector with 57 °C fixed (static) temperature threshold, including special base

BEAMHKR Heater Kit

Heater Kit (Indent only, used with 6500SE-34 & 6500RSE)

IHD Kit

Conventional bi-metallic indicating heat detectors with remote sensor. Fixed threshold: 57 °C (blue) or 125 °C (black). NZS 4512-compliant

2351E Detector

Conventional photoelectric smoke detector

BEAMHK Heater Kit

Heater Kit (Indent only, used with 6500SE-34 & 6500RSE)

7251CPI Detector

C Series intelligent addressable plug-in Pinnacle™ high-sensitivity photoelectric smoke detector. Configurable alarm threshold.

22051TLE-34-IV Detector

Photo, Thermal & IR detector

2351TEM Detector

Conventional multi-criteria detector. Photoelectric smoke, configurable as low, medium, or high sensitivity. 58 °C rate of rise heat sensor

2251BPI Detector

Photoelectric analogue addressable plug-in smoke detector

4351E Detector

Conventional heat detector with 78 °C fixed alarm temperature threshold

OSIDCI Interface

Conventional Beam Interface (OSID Interface) Board

5251BPI Detector

Analogue addressable heat detector with 57 °C fixed (static) temperature threshold

5351E Detector

Conventional rate of rise heat detector with 58 °C fixed alarm temperature threshold

5251RBPI Detector

Analogue addressable rate of temperature rise heat detector with 57 °C fixed (static) temperature threshold

5351TE Detector

Conventional heat detector with 58 °C fixed alarm temperature threshold

IHD*-V

Conventional indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant

IHD*E-V

Conventional indicating heat detectors. Encapsulated. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant

DETREM Remote LED Indicator

Remote LED indicator

BCK-200B Detector Kit

Black cover for System Sensor detectors

IHD*R-V

Conv. indicating heat detectors. Terminals for remote indicator. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant

IHD*EAR-V

Conv. indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant

RMK400AP Mounting Kit

Recessed mounting kit for detectors, ivory

HD*-V

Conv. non-indicating heat detectors, with or without encapsulation. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512:1997-compl

2W-B Detector

2-wire conventional photoelectric smoke detector

2WTA-B Detector

Multi-criteria detector, 2-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and alarm sounder

4W-B Detector

4-wire conventional photoelectric smoke detector

4WT-B Detector

Multi-criteria detector, 4-wire, with photoelectric smoke sensor and heat sensor with 58 °C fixed alarm threshold

4WTR-B Detector

Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and relay

4WTAR-B Detector

Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold, sounder, and relay

2012/24AUSI Detector

Photoelectric Smoke Alarm 4-wire, 12 V / 24 V with 9 V battery AS 3786:2014

PC614 Detector

Conventional carbon monoxide (CO) and rate-of-temperature-rise heat detector. Suitable for detecting slow-smoldering and fast-flaming fires.

RFD-2000X Flame Detector

Ultraviolet + Infrared flame detector

RFD-3000X Flame Detector

Three-band infra-red flame detector

LHD

Linear heat detection cable. Please note that Pertronic-Anbesec LHD Cable is preferred for new installations

Bases

B401 Detector Base

Mounting base for conventional plug-in System Sensor detectors. Available in white and ivory

B501AUS Detector Base

Plug-in base for analogue addressable detectors. Standard depth for 200 series detectors.

B401R Detector Base

Special B401 Base with 470 ohm Series Resistor

B501AP Base

Plug-in base for analogue addressable detectors and loop-powered devices. Extra depth to suit alarm devices such as addressable strobes.

B401DG Detector Base

Deep mounting base for conventional plug-in System Sensor detectors

B524RTE Detector Base

Plug-in base with change-over relay for analogue addressable detectors

WB-1AP Base Enclosure

Base Enclosure for Humid Environments, for use with Base Models: B501AP, B501, B401, B401R

SMK400E Kit

Surface Mounting Adaptor Kit

B524HTR Heated Base

Analogue Addressable Heater Base

Manual Call Points

AAMCPT Manual Call Point

Analogue Addressable Manual Call Point - Testable

CPPIN-3T MCP

Conventional indicating manual call point, flush mount, excluding back box

AAMCP-TWP-MK2 Manual Call Point

Analogue Addressable Weatherproof Manual Call Point - Testable

CPPIN-3TWP-MK2 MCP

Weatherproof conventional manual call point

AAMCPT-E Manual Call Point

Analogue Addressable MCP in Euro Style Enclosure

CPP-TWP-MK2 MCP

Conventional Weatherproof MCP - Testable

CPP MCP

Conventional manual call point with rocker switch. Available in red, yellow, and white

CPPINT-E MCP

Euro style conventional indicating manual call point

CPTSTPRWP Weatherproof

A tough, transparent, weatherproof polycarbonate shield and frame that fits over a manual call point

CPTST series

A tough, transparent, polycarbonate shield and frame that fits over a manual call point. Fitted with warning sounder

CPTSTPRHTR Call Point Stopper

A tough, transparent, polycarbonate shield and frame that fits over a manual call point, with built-in 230 Vac heater

CPBACKBOX Back Box

Back box for mounting a Pertronic manual call point on a flat surface

CPP-DPDT MCP

Double-Pole double-throw non-engraved manual call point. Available in red and white

PS200 FLAP

Transparent hinged plastic cover for Euro Style manual call points, to reduce false alarms caused by accidental MCP activation

CPPFPL Mounting Plate

Fascia panel for flush-mounting Pertronic Manual Call Points in place of large old manual call points (break-glass alarms)

KACSGW MCP Window

Replacement windows for Manual Call Points, including Snapglaze and Break-Glass types

CPPTK MCP Test Key

Test key for Pertronic testable manual call points

Modules

AM

Apartment module for NZS 4512 Type 5 analogue addressable fire alarm systems

Isolate Timer Module

The Pertronic Isolate Timer Module isolates a zone for a user-programmed time period, after which the zone is automatically re-enabled

F220 Fan Controls

The F220 Fan Control System is used with the F220 fire panel to monitor and control air handling equipment for AS 1670.1-compliant.

AALR-MF Loop Responder

Multi-Function Loop Responder

F100A Fan Controls

F100A Fan Controls are used in Pertronic F100A, F120A and F220 fire alarm systems. Designed to comply with AS 1670.1-compliant.

F100LRU Loop Relay

AA output module with 4 individually addressable channels: each with a switched, supervised 24 Vdc output, and a volt-free contact

Solenoid Interface

Interface units which allow allow analogue addressable control modules to activate and supervise a wide range of solenoids

8SAAIB Module

8 Spur Analogue Addressable Isolator Board

M500M Module

Analogue Addressable Monitor Module

M500R Module

Analogue Addressable Relay Control Module

M500S Module

AA Relay Module with Monitored Output

M500X Module

Analogue Addressable Zone Isolator Module

M500DMR Module

Analogue Addressable Dual Input + Dual Relay Output Module

M501M Module

AA Mini Monitor Input Module

ISO524-1 Isolator

Analogue Addressable Short Circuit Unit

M210E-CZR Module

Interface between a conventional detection zone and an AA fire panel. Especially suitable for zones in areas subject to explosive atmosphere

M210EA Module

Intelligent addressable (IA) monitor module with one input channel. Built-in isolator for the IA loop

M210EA-CZR Module

IA conventional zone interface. Connects a zone of conventional smoke detectors to an IA system. Built-in isolator for the IA loop

M201EA-240 Module

Intelligent addressable control module with one 2-pole output relay (1 pole NO, 1 pole NC). Built-in loop isolator

M201EA Module

Analogue addressable control module with one output channel. Built-in isolator for the AA loop

M220EA Module

Analogue addressable monitor module with two input channels. Built-in isolator for the AA loop

M221EA Module

Analogue addressable control & monitor module with two input channels and one output channel. Built-in isolator for the AA loop

CR-6 Module

Analogue addressable control module with six voltage-free form-C (change-over) relay contacts

IM-10 Module

Analogue addressable monitoring module with ten individually addressable inputs for normally-open contact devices

SC-6 Module

Analogue addressable control module with six supervised relay circuits for switching AC, DC, or audio

M200E Mounting Box

Analogue Addressable Euro Module Surface Mount Box

PMB125 Mounting Box

Analogue Addressable Module Box

F100ZIPB Opto-Isolated IP Board

Eight-way opto-isolated input board for the Pertronic analogue addressable loop responder and multi-function loop responder

Aspirating Smoke Detection

VESDA-E VES-A10-P

Four-inlet aspirating smoke detector with individually-addressable inlet pipes and LCD display

VESDA-E VES-A00-P

Four-inlet aspirating smoke detector with individually-addressable inlet pipes and LED display

VESDA-E VEP-A00-1P

VESDA-E VEP with LEDs, 1 pipe

VESDA-E VEU-A10

VESDA-E VEU with 3.5" Display

VESDA-E VEU-A00

VESDA-E VEU with LEDs

VESDA VLF-500

VESDA Laser Focus Detector

VESDA VLF-250

VESDA Laser Focus Detector

VESDA VLI

VESDA VLI Series Detector

VESDA Display Modules

Display modules for VESDA aspirating smoke detectors

VRT-100 Programmer

Programmer for VESDANet devices including VESDA aspirating smoke detectors

VRT-300 Socket Module

Remote Box with VESDAnet Socket

FAAST FLEX Aspire v3.10

Windows® app. for designing and specifying FAAST FLEX ASD systems including pipe network configuration. NOTE: Does not support VESDA systems

VESDA VSC v3.12

Management application for Xtralis fire and gas detection systems including VESDA and ICAM smoke and gas detectors and ancillary devices

VESDA Aspire Software v3.12

A Windows®-based application for designing and specifying VESDA aspirating smoke detection systems

FAAST LT-200 Analogue Addressable

Analogue Addressable Aspirating Smoke Detector

FAAST LT-200 Conventional

Stand-Alone Aspirating Smoke Detector

FAAST FLEX

Single or dual input ASD. Silent operation. Suitable for sub-zero environments down to -40°C. Simple DIP-switch configuration.

FAAST PipeIQ v3.0.0

A Windows®-based application for designing and specifying FAAST aspirating smoke detection systems

AUX24V-1.5PSU-BLK Power Supply

24 Volt 1.5 Amp Auxiliary Power Supply in Lockable Battery Cabinet (FAAST Power Supply)

VESDA VLF MCC

VESDA VLF Multi-Function Control Card

VIC-010 Interface Card

VLF Network Interface Card

ASD-FAAST-LTIF Interface

FAAST LT Conventional Interface

VSP-850-G In-Line Filter

VESDA Rectangular Grey Inline Filter

VHX-0200 Interface

High level interface between VESDAnet and a personal computer (PC). Allows a user easily configure, manage and monitor a VESDA network

VSP-005 Filter

It's used to replace filter cartridges in VESDA VLC, VLF, VLP and VLS detectors.

Aspirating Pipes & Fittings

Aspirating Pipes & Fittings

VSP-860 Kit

A funnel-shaped sampling nozzle and a kit of parts for installing the nozzle inside a cold storage facility.

VSP-962 VESDA-E Filter

Genuine replacement two-stage smart filter cartridge for VESDA-E aspirating smoke detectors

ASD-F-SEN-SSE Sensor Head

Replacement smoke sensor for FAAST LT-200 series aspirating smoke detectors

ASD-FAAST-FILTER30M Filter

30 Micron Filter for FAAST XT, XM & XS Series aspirating smoke detectors.

ASD-FAAST-FILTERLT-2 Filter

Replacement filter for FAAST LT-200 aspirating smoke detectors. Two-Pack

CLC-MON-N9P Cable

Flexible RS-232 extension lead with DB9 male and DB9 female connectors and straight-through connection

USBETH USB-Ethernet Adaptor

FAAST USB-Ethernet IP Address Adaptor

Explosive Atmosphere Detection

ORB-HT-51151 Detector

Intrinsically safe conventional heat detector with 77°C fixed (static) temperature threshold (BS EN 54-5 Class BS)

ORB-OP-52028 Detector

Intrinsically safe conventional photo-electric smoke detector (BS EN 54-7)

22051EISE Detector

Intrinsically-safe analogue addressable plug-in photoelectric smoke detector

AALR-MF Loop Responder

Multi-Function Loop Responder

IST200E Module

Interface module for connecting Y72221 galvanic isolator & 22051EISE detectors to a Pertronic analogue addressable loop circuit

KFD0-CS-EX-1.51P Galvanic Isolator

Single channel galvanic isolator for use with conventional MCPs, fire and smoke detectors located in hazardous areas

Y72221-L4 Galvanic Isolator

Galvanic isolator for analogue addressable IS detectors. Pepperl & Fuchs type KFD0-CS-Ex1.54-Y2

ISMTL5561 Detector Interface

Dual interface with galvanic isolation for use with conventional MCPs, fire, heat and smoke detectors located in hazardous areas

ISGAIFNZSSAP Interface

Interface for connecting a galvanically-isolated detection zone to a Pertronic conventional FACP (F1, F4, F16e), or Loop Responder

PS200 FLAP

Transparent hinged plastic cover for Euro Style manual call points, to reduce false alarms caused by accidental MCP activation

MCP3A

Intrinsically safe conventional manual call point with back-box. Suitable for surface or flush mounting

WCP3A

Intrinsically safe IP67 weatherproof conventional manual call point with back-box for surface mounting

ORB-MB-50018 Base

Base for Orbis intrinsically-safe plug-in conventional detectors

M210E-CZR Module

Interface between a conventional detection zone and an AA fire panel. Especially suitable for zones in areas subject to explosive atmosphere