CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Fire Alarm Control Panels

Four-Zone Conventional Fire Alarm Control Panel

Products » Panels, Networking & Utilities Software » Fire Alarm Control Panels
Pertronic

F4-3

Datasheet
Manual
ENQUIRE ABOUT THIS PRODUCT

The Pertronic F4-3 is a four-zone fire alarm control panel for use with conventional detectors.

The F4-3 supports Smoke Detectors, indicating Manual Call-Points (MCP) and indicating heat detectors, and has the facility to internally mount one or two 20 Watt evacuation amplifiers. It provides an option for brigade connection and complies with the requirements of New Zealand Standard NZS 4512:2010 and the New Zealand Building Code.

Features

  • ‘Normal’, ‘Defect’ and per circuit ‘Fire’ indication on front panel
  • ‘Internal Bell Cut-Off’ and ‘External Bell Cut-Off’ (BCO)
  • Alarm reset available from a front panel key-switch
  • Trial Evacuation key-switch
  • Fire & Defect C/O relays with Fire relay Isolate switch
  • Automatic Alarm Verification Facility (AVF) provides substantial protection against transient false alarm activation
  • Supervised bell circuit with 10 kΩ EOL resistor
  • Maximum of two 20 Watt 100 Vrms line amplifiers with voice evacuation message
  • ‘Battery Absent’ detection circuitry
  • Earth leakage supervision
  • Integrated Alarm and Defect piezo for audible warning
  • On-board System ‘Defect’ LED indicates source of fault
  • Door Interlock
  • Brigade ‘Isolate’ and ‘Test’ switches
  • Electrically isolated interface to an alarm transmitter (SGD)
  • DBA mode ‘Non Latching, Bell Only’ configuration available (on Circuit 4)
  • Automatic daily load test with automatic ‘Battery Absent’ detection circuitry
  • Complies with the requirements of New Zealand Standard NZS 4512:2010

Easily configured for NZS 4512:1997 compliance

Click here for index drawings.

Ordering Information

Product Code

Description

F4FS-3

F4 Panel Front Service - 12 Volt

F4RS-3

F4 Panel Rear Service - 12 Volt

F4FS-3EA

F4 Front Service Panel with 20W Evac - 12 Volt

F4RS-3EA

F4 Rear Service Panel with 20W Evac - 12 Volt


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL